On this page

    Pool School, Safety Covers

    Is My Pool Cover a Safety Cover?

    Active Pool Supply · Updated September 23, 2026

    The short answer

    Read the label. ASTM F1346 sorts every pool cover into three named classes and requires the label to say which one you have: Power Safety Cover, Manual Safety Cover, or Other Covers. The first two are safety covers. Other Covers pass no performance test at all, and their labels have to carry the flat statement that the product is not a safety cover. A winter cover, a solar blanket and a debris cover are all Other Covers. A label that is missing or unreadable means the cover cannot be verified, so treat it as an Other Cover until the manufacturer replaces the label.

    Read the label. That is the test.

    Find the label sewn or riveted to your cover and look for a classification. ASTM F1346 puts every pool cover into one of three named classes, and clause 8.12 requires the label to state which class the product holds. A Power Safety Cover or a Manual Safety Cover is a safety cover. Anything else is not, and a cover that is not one has to say so on its label in plain words. No label, or one you cannot read, means unverified, and unverified means you treat it as a winter cover.

    The three classes, and why the third one matters most

    Section 4 sets out the cover classifications, and there are exactly three.

    Class What it is Tests it must pass A barrier?
    Power Safety Cover (PSC) Put on and taken off by a motor Load, deflection, drainage, openings, plus Section 10 controls Yes, a high level of safety for a child under five
    Manual Safety Cover (MSC) The same barrier, placed by hand The same list without Section 10 Yes, though securing it takes longer
    Other Covers (OC) Everything else None No, and the design can be hazardous around a small child

    Here is the part almost nobody publishes. An Other Cover is not a weaker safety cover. It is a class that passes no performance test whatsoever. Clause 4.3.1 asks it to satisfy the materials clauses and the labeling clauses, and stops. No weight test, no drainage test, no openings test, no perimeter test.

    Your blue winter tarp, solar blanket and leaf cover all land there. The standard names each and routes it back to Other Covers, to be taken off completely before anybody swims.

    How to read the label, line by line

    Section 8 binds every cover, safe or not, so a warning label proves nothing by itself.

    On every cover

    • The manufacturer or responsible party, which may be a private label distributor.
    • The signal word WARNING, preceded by a triangle holding an exclamation point, at least as tall as the signal word's letters.
    • Directly below it, the fixed message AVOID DROWNING RISK. It has to come first.
    • Then the hazard statements that apply, from the chart at Figure 1: stay off a cover that will not take weight, a child underneath cannot be seen, clear standing water, remove the cover before anyone swims.

    Only on a safety cover

    Clause 6.3 adds three markings an Other Cover does not need: the manufacturer's name, the date of manufacture or installation, and a direction to inspect for early wear and deterioration.

    Only on a cover that is not one

    Two tells. The last row of Figure 1 makes a cover that fails the safety requirements add a statement that it is not a safety cover, flat, in those words. And color: clause 8.3 prints its signal word black on an orange panel, with a black alert triangle holding an orange exclamation point. Clause 8.4, the color clause, is written for the two safety classes only, so orange means not a safety cover.

    The label must be permanent, or at least hard to remove, and sit where fitting will not strip it. If yours is gone or unreadable, clause 8.9 says to ask the manufacturer for replacements.

    What a safety cover has to survive

    Static load: 485 lb, in three pieces

    For a pool whose width or diameter is more than 8 ft, the cover has to hold 485 lb. At 8 ft or under, 275 lb. Careful, because this is widely garbled: the 8 ft measures the pool, not the cover, and not the drop from the cover edge to the water. Nearly every residential pool is wider than that, so yours is a 485 lb cover. The 275 lb case is spas and small wading pools.

    485 lb stands for two adults plus a child, sized for a rescue. It does not arrive as one block. Three weights go on: 225 lb, 210 lb and 50 lb, each spread across a square foot, all three inside a 3 ft radius, for 5 minutes. Then the same load moves between attachment points, 4 to 6 ft in from the pool wall, where covers give way. Nothing may tear enough to let a weight through.

    Perimeter deflection

    Put 50 lb on the cover 4 to 6 ft in from the side and it must not sag far enough to open a gap at the edge. What has to be kept out is an ellipsoid, 3.7 in by 5.7 in and at least 12 in long, weighing 36.6 lb. The scenario: one child falls onto the cover, and the test asks whether a second could slide into the water down the side.

    Openings: a 4.5 in sphere under 40 lb

    No opening in the cover, and no gap at its edge, may let through a solid faced sphere 4.5 in across when 40 lb, give or take a pound, is pushed steadily against it. Clause 7.4 makes it a strength requirement too: the opening must not be forceable to a size that passes the sphere. The 4.5 in is head breadth, measured on a fifth percentile seven month old, the age at which half of babies can creep on hands and knees and reach a pool unaided.

    Drainage: 30 minutes, judged by a toddler shape

    A safety cover has to shed substantially all standing water within 30 minutes of the rain letting up. The lab version of rain is a spray applied evenly at 10 gal a minute for every 1,000 sq ft of pool, for half an hour.

    The pass mark is not dryness. A torso shaped object stands in for a three year old: 32 in long, 9 in wide and 5 in deep, weighing 36.6 lb. It lies face up, parallel to the edge and two to three feet in from it. Three minutes later the cover fails if the water still there completely covers that torso. Plainly: drain fast enough that a small child could not drown in the puddle on top. Residual water is expected.

    Through both load tests every anchor, strap, spring and control has to stay closed and keep working. Fastenings also have to resist a child: a key, a lock, a special tool, or a spot 5 ft up with nothing to climb.

    Two things you will read that are not true

    "A safety cover will not let more than one inch of water collect." That line is everywhere and it is not in the standard. There is no one inch figure in F1346, anywhere. The real rule is the one above, judged by whether what remains would swallow a 36.6 lb toddler shape laid on the cover. A listing quoting you an inch is copying a secondary summary, not the specification.

    "The openings have to stop a 4 inch ball." Both numbers are real and they belong to different documents. F1346 uses a 4.5 in sphere at 40 lb for openings in a cover. The 4 in sphere is the barrier rule, used by the model swimming pool and spa code and the federal barrier guidelines to measure the gaps in a fence. Judge a cover at 4.5 in and a fence at 4 in.

    A note on our own accuracy. Every clause and figure here comes from the published text of F1346, adopted in 1991 and reapproved since. The current revision, F1346-23, is paywalled and we have not read it.

    There is no certification, and that is not a scandal

    Search the published standard for the word and it does not appear. ASTM writes specifications. It does not test products, approve them or list them. Its own catalog entry calls F1346 a specification with performance tests that show compliance or noncompliance.

    A cover claiming F1346 is saying one of two things. Usually it is a manufacturer's declaration: the manufacturer states that its cover meets, or meets and exceeds, the performance requirements. It rests on the manufacturer's own testing. The stronger one is an independent lab evaluation, which here means UL. Underwriters Laboratories runs classification programs, and some powered cover manufacturers give a UL file number with a statement that UL classified the system as a power safety cover to F1346. Ask for that number.

    Be suspicious of the standard's number followed by "certified", "approved" or "rated". The standards body does none of those three things. Sound phrasings are "meets ASTM F1346", "built to ASTM F1346", and, where a file number backs it, "UL Classified to ASTM F1346".

    Does a safety cover replace a fence?

    In most places, no. This is the question where a comfortable answer gets somebody hurt.

    The International Swimming Pool and Spa Code, the model most jurisdictions build on, waives the barrier sections in two cases: a spa or hot tub with a lockable F1346 cover, and a swimming pool with a powered F1346 cover. The code body's commentary is explicit: a manually installed cover does not earn that relief even when it complies, because putting one on by hand is involved enough that it would not be done every time the pool goes unused. The federal barrier guidelines say powered too.

    States layer their own rules on top. California is the permissive end: its pool safety statute lists a safety pool cover, manual or powered, among the qualifying drowning prevention features, and the test it sets is the label, which has to verify the cover meets the F1346-23 specification. New York is the strict end: a swimming pool needs its permanent barrier whether or not a safety cover is fitted, though a spa with a complying cover is exempt.

    Every safety cover we sell is a manual one. Under the model code that is not a fence substitute. Check your local code and keep the fence.

    Above ground pools

    Wading pools, hot tubs, spas and swimming pools are all inside the scope, and above ground pools are never carved out of it. They are never discussed either, and the tests show why.

    The openings test measures the gap where the cover edge meets a deck, a coping wall or the top of the pool. A deck, in the standard's definition, is the area abutting the pool built of wood, concrete, brick or stone, and it may carry the cover's supports. The load and deflection tests want anchor points several feet in from the pool wall. An above ground pool standing on grass has none of that.

    That last step is our reading, not a line in the standard. The conclusion holds either way: a cover winched down on a cable, or clipped to the top rail, is an Other Cover. If you meet one advertised against F1346, ask which of the three classes its label names.

    What this means when you are shopping

    Every cover on our safety cover pages is a Manual Safety Cover: fabric panels held over the water by straps, springs and anchors set into the deck. A mesh cover such as the King99 passes rain and snowmelt through the weave, which clears the 30 minute drainage rule and is why mesh needs no pump on top of it. A solid cover such as the Emperor blocks the light instead and moves water off through a drain panel or a cover pump.

    The anchors are not an accessory. They are what the load and deflection tests are really measuring, because a cover only holds 485 lb if what it is tied to holds 485 lb too. In a concrete deck that means a brass anchor set into the slab, raised with a 1/4 in hex key to take the spring and screwed back flush for the swimming season. Brass, because it spends its life in wet concrete.

    Then do the thing this page is about. Find the label, read the classification, and keep the sheet with the date on it.

    Products in this guide

    Questions

    What if my pool cover has no label?

    Then you cannot verify it, and the safe assumption is that it is not a safety cover. The standard requires the label to be fixed on permanently, or at least so that it is not easy to pull off, and to sit where fitting the cover will not tear it away. Clause 8.9 tells an owner with a missing or unreadable label to ask the manufacturer or responsible party for replacements. Do that. A cover with no classification on it is a cover with no claim behind it.

    Does a pool safety cover count as a fence?

    Usually not. The model swimming pool and spa code drops the barrier requirements for a spa or hot tub with a lockable F1346 cover, and for a pool with a powered F1346 cover. The code officials who wrote the commentary say directly that a cover installed by hand does not earn that relief, because putting one on manually is slow enough that nobody would do it every time the pool went unused. California is more permissive and accepts a manual cover, with the label as the legal test. New York requires the pool barrier either way. Check your own jurisdiction and plan on keeping the fence.

    Is a pool safety net the same as a safety cover?

    Not unless its label says so. F1346 does not care what a product is called, only which of the three classes it is labeled as. A net that names no classification has made no claim under the standard. Ask a second question too: a safety cover has to stop a solid faced sphere 4.5 in across from being pushed through any opening under a 40 lb load, and an open mesh net has to answer that test the same way a fabric panel does.

    What is the best pool cover for child safety?

    The standard ranks them for you. A Power Safety Cover and a Manual Safety Cover are both described as giving a high level of safety for a child under five, with the powered one faster to secure and therefore likelier to actually be closed. An Other Cover is not a barrier, and the standard warns that its design can itself be hazardous around a small child. If code relief matters to you, only the powered class gets it under the model code, and no cover of any class is a substitute for a fence plus supervision.

    Is an automatic pool cover a safety cover?

    Only if it passed. The standard defines an automatic cover as one driven by a motor through a control, then routes it to the powered safety class or to Other Covers on the test results. One that qualifies also has to meet Section 10: a switch that stops the cover the instant you let go, reversing from a dead stop mid travel, wiring to the National Electrical Code article for pool equipment, a fixed control with the whole cover in view, and a key, lock or mounting 5 ft up so a child cannot run it.

    Does ASTM F1346 cover above ground pools?

    They are never carved out of the scope, and they are never discussed in it either. But the openings test measures the gap where the cover edge meets a deck, a coping wall or the pool rim, and the load and deflection tests want anchor points several feet in from the pool wall. An above ground pool standing on grass offers none of that. Our reading is that a cover winched down on a cable, or clipped to the top rail, is an Other Cover.

    What is the difference between UL Classified and meeting ASTM F1346?

    Who is doing the talking. "Meets ASTM F1346" is the manufacturer declaring that its product passes the tests in the specification. "UL Classified to ASTM F1346" means an independent lab evaluated the product against the same specification and issued a file number you can look up. Both phrases are legitimate. ASTM itself neither tests nor approves anything, so the standards body is never the third party in either claim.

    Find your safety coverEvery pool safety cover by size, mesh and solid, with the step cut out where your pool has one.Shop pool safety covers