  • Genuine Raypak The factory 014325F ignition control module.
  • Single try This is the single try version. Raypak lists a multi try ignition control as a separate part number.
  • MVB and Xtherm Referenced for the Raypak MVB and Xtherm heater lines.
  • Controls the light off sequence The ignition control runs the purge, spark and flame proving steps every time the heater is called.
  • A common no fire cause A heater that clicks but never lights, or locks out repeatedly, often traces back to this module.
  • Direct swap Replaces the original module in the heater control housing.
Full description and specifications ↓

Need a hand?

Bilingual support from pool professionals.

Send us a message

A pool professional will get back to you, usually the same business day.

About Raypak 014325F PIM Ignition Control Single Try, SKU RAY-014325F. We will include it with your message.

We use your details to answer this message and nothing else.

Frequently bought together

Current item Raypak 014325F PIM Ignition Control Single Try
Raypak

014325F PIM Ignition Control Single Try

$58799
Raypak Genuine OEM Protek Shield Module Assembly, 017960F
Raypak

Genuine OEM Protek Shield Module Assembly, 017960F

$5199
Raypak Heat Pump Digital Control Board 9350/9353 5450-8450, 100-10000347
Raypak

Heat Pump Digital Control Board 9350/9353 5450-8450, 100-10000347

$29699
Raypak Genuine OEM 3/4" IID Pool Heater Natural Gas Electronic Valve, 003900F
Raypak

Genuine OEM 3/4" IID Pool Heater Natural Gas Electronic Valve, 003900F

$25199
Raypak Genuine OEM Propane and Natural Gas Pilot, 002003F
Raypak

Genuine OEM Propane and Natural Gas Pilot, 002003F

$8199
Raypak Kit-PC 3-Wire Board Controller IID for 206A-408 Pool Heaters, 100-10000345
Raypak

Kit-PC 3-Wire Board Controller IID for 206A-408 Pool Heaters, 100-10000345

$32499
Raypak 100K Temp Sensor Kit, 9350/9353 and 5450-8450 Heat Pumps, H000329
Raypak

100K Temp Sensor Kit, 9350/9353 and 5450-8450 Heat Pumps, H000329

$10299
Subtotal

Similar products

Other products people compare with this one.

Product details

Raypak 014325F is the PIM ignition control in its single try version. Raypak references it for the MVB and Xtherm heater lines.

What the module does

Every call for heat runs through the ignition control. It handles the pre purge, energizes the ignitor, opens the gas valve, and watches for a proven flame within its trial window. If flame is not proved, it shuts the gas off and locks out. That last behavior is the reason a failed module is so often mistaken for a gas supply problem: the heater goes through the motions and then stops, with no obvious fault at the burner.

Single try versus multi try

This is the single try control, meaning one ignition trial per call for heat. Raypak also lists a multi try ignition control under its own part number. The two are not interchangeable in practice, so match the version your heater was built with rather than choosing on price or availability.

Before replacing it

Rule out the simple causes first. Gas pressure, a cracked or contaminated ignitor, and flame sense wiring all produce the same no fire symptom, and they are cheaper to check than a control module is to swap.

Specifications
Brand Raypak
Manufacturer part number 014325F
Type PIM ignition control
Ignition attempts Single try
Listed for Raypak MVB, Xtherm
Ships Parcel

Request a quote

Need a volume price, a freight quote, or pricing in writing before you order? We reply the same business day.

Request a quote

Customer reviews

More from Raypak

Questions and answers

What people ask about this product, answered by our pool techs.

Is this the single try or the multi try control?
Single try. Raypak lists the multi try ignition control under a different part number, so match the one your heater was built with.
Which heaters is it listed for?
Raypak references it for the MVB and Xtherm.
My heater clicks but never lights. Is this the part?
It is one of the usual suspects. The ignition control runs the whole light off sequence, so a failed module can leave the heater cycling without ever proving flame. Confirm gas supply and the ignitor before swapping it.
Is it a genuine Raypak part?
Yes. It is the Raypak OEM module, part number 014325F.
Ask your own question