Pentair 473665 probe thermistor defrost sensor for pool and spa heat pumpsPentair 473665 Probe Thermistor Defrost Sensor for Pool and Spa Heat Pumps In stock$4999
Pentair 473665 probe thermistor defrost sensor for pool and spa heat pumps

Pentair 473665 Probe Thermistor Defrost Sensor for Pool and Spa Heat Pumps

Ask a questionMPN 473665
$4999
In stock

30 day returns · Easy, with prepaid labels provided

Quick overview

  • Genuine Pentair part The factory defrost sensor, part number 473665.
  • Thermistor probe Reads temperature as resistance and reports it to the heat pump control.
  • Defrost duty This is the sensor the unit uses to decide when the coil needs a defrost cycle.
  • ThermalFlo Titanium Listed as the defrost sensor for the Pentair ThermalFlo Titanium heat pump.
  • Pool and spa heat pumps Pentair describes it as a pool and spa heat pump replacement part.
  • Direct replacement Swaps for the original probe without changing the control board.
Full description and specifications ↓

Need a hand?

Bilingual support from pool professionals.

Send us a message

A pool professional will get back to you, usually the same business day.

About Pentair 473665 Probe Thermistor Defrost Sensor for Pool and Spa Heat Pumps, SKU PUR-151-1802. We will include it with your message.

We use your details to answer this message and nothing else.

Frequently bought together

Current item Pentair 473665 Probe Thermistor Defrost Sensor for Pool and Spa Heat Pumps
Pentair

473665 Probe Thermistor Defrost Sensor for Pool and Spa Heat Pumps

$4999
Pentair Genuine OEM MasterTemp/Max-E-Therm 6-Button Control Board Kit, 461105Z
Pentair

Genuine OEM MasterTemp/Max-E-Therm 6-Button Control Board Kit, 461105Z

$53899
Pentair MasterTemp 125 Manifold Kit, 474972
Pentair

MasterTemp 125 Manifold Kit, 474972

$28399
Pentair Tube Sheet Coil Assembly Kit for 250NA 250LP MasterTemp Heater, 474059
Pentair

Tube Sheet Coil Assembly Kit for 250NA 250LP MasterTemp Heater, 474059

$93499
Pentair Combustion Chamber Assembly for Max-E-Therm Heaters, 474957
Pentair

Combustion Chamber Assembly for Max-E-Therm Heaters, 474957

$37399
Pentair UltraTemp Capacitor Replacement with Bracket, 440V, 473731Z
Pentair

UltraTemp Capacitor Replacement with Bracket, 440V, 473731Z

$9299
Pentair Flame Holder Kit for MasterTemp Model 125 Heater Burner System, 474994
Pentair

Flame Holder Kit for MasterTemp Model 125 Heater Burner System, 474994

$15199
Subtotal

Similar products

Other products people compare with this one.

Product details

The Pentair 473665 is the probe thermistor defrost sensor for pool and spa heat pumps. Pentair lists it for the ThermalFlo Titanium heat pump.

What a defrost sensor does

A heat pump pulls heat out of the outside air, and in cool weather that leaves the evaporator coil colder than the air around it. Moisture then freezes onto the coil and chokes off the airflow the unit depends on. The defrost thermistor is the probe that watches that coil temperature, and its reading is what the control uses to start and end a defrost cycle.

Why a bad probe matters

A thermistor that has drifted or failed does not stop the heat pump, it misleads it. The unit either defrosts on a mild day when there is nothing to melt, or ices up in the cold because the control never saw the temperature drop. Either way it heats badly and works harder than it should. Replacing the probe puts the control back on real numbers.

Specifications
Brand Pentair
Manufacturer part number 473665
UPC 788379769727
Type Probe thermistor defrost sensor
Fits Pentair ThermalFlo Titanium heat pump
Application Pool and spa heat pumps
Shipping weight 0.1 lb
Ships Parcel

Request a quote

Need a volume price, a freight quote, or pricing in writing before you order? We reply the same business day.

Request a quote

Customer reviews

More from Pentair

Questions and answers

What people ask about this product, answered by our pool techs.

What does the defrost sensor do?
It is a thermistor probe that tells the heat pump control how cold the coil is, which is how the unit decides whether it needs to run a defrost cycle.
Which heat pump is it for?
Pentair lists it for the ThermalFlo Titanium heat pump, as a pool and spa heat pump part.
What happens when this sensor fails?
A probe reading wrong sends the control bad information, so the unit can defrost when it does not need to, or ice up when it should have defrosted.
Is this a genuine Pentair part?
Yes. It is Pentair part number 473665.
Ask your own question